CONTROL BOARD CABINET
HIERARCHY
Hierarchy Name | DIST |
System Name | SNOW MELTING |
Subsystem Name | CONTROLLER |
Asset Name | CONTROL BOARD CABINET |
Acronym | CBCT |
ADS Code | DIST90E-CBCT |
FLOW Enabled | False |
Service Life | 20 YEARS |
Equipment Utilization | 50,000 HOURS |
STANDARD CROSSWALK
ACRM Asset Class Number | 5002; 10006; 99007 |
ACRM Asset Description | CONTROL EQUIPMENT - SWITCHING AND DISTRIBUTION; DEI-ICING PIPING AND EQUIPMENT; SNOW MELTING EQUIPMENT (NON-STRUCTURAL) |
ACRM Asset Useful Life (yr) | 25; 15; 15 |
UniFormat 2010 Code (Option 1) | D3070.10: SNOW MELTING |
UniFormat 2010 Code (Option 2) | Reference cannot be found! |
ASSET TAG PLACEMENT
Tag Strategy | ON ASSET |
Tag Position | SIDE |
REQUIRED ASSET RECORDS
ENGINEERING ATTRIBUTES TABLE
Description | Attribute (ASSETATTRID) | UNIT OF MEASURE | DATA TYPE | DOMAIN ID |
---|---|---|---|---|
ADDRESSABLE | CONTROL_PANEL_10 | N/A | ALN | _YESNO |
AMP HOUR | CONTROL_PANEL_12 | AH | NUM | |
AMPERAGE | CONTROL_PANEL_02 | AMP | ALN | |
CABINET TYPE | CONTROL_PANEL_15 | N/A | ALN | |
CONTROL VOLTAGE | CONTROL_PANEL_11 | V | ALN | |
DRAWING NUMBER | CONTROL_PANEL_14 | N/A | ALN | |
ENCLOSURE TYPE | CONTROL_PANEL_08 | N/A | ALN | |
FACLEVEL | CONTROL_PANEL_13 | N/A | NUM | _TRALTIMERATG |
FREQUENCY | CONTROL_PANEL_04 | HZ | ALN | |
FULL LOAD AMPS (FLA) | CONTROL_PANEL_06 | AMP | NUM | |
INSTALLER NAME | CONTROL_PANEL_21 | N/A | ALN | |
MOUNT HARDWARE TYPE | CONTROL_PANEL_22 | N/A | ALN | |
OUTDOOR RATED | CONTROL_PANEL_23 | N/A | ALN | _YESNO |
PHASE | CONTROL_PANEL_05 | N/A | ALN | _PHASE |
POWER | CONTROL_PANEL_03 | W | NUM | |
RACK ELEVATION | CONTROL_PANEL_17 | N/A | ALN | |
RADIO FREQUENCY | CONTROL_PANEL_19 | N/A | ALN | _RADIOFREQ |
RATING | CONTROL_PANEL_24 | N/A | ALN | |
ROOM TYPE | CONTROL_PANEL_16 | N/A | ALN | |
STATION | CONTROL_PANEL_09 | N/A | ALN | _STATION |
TESTING | CONTROL_PANEL_20 | N/A | ALN | _YESNO |
TYPE | CONTROL_PANEL_18 | N/A | ALN | |
VOLTAGE | CONTROL_PANEL_01 | V | ALN |
ASSET SUB TYPE AND ATTRIBUTES TABLE
CONTROL PANEL | CONTROL PANEL, ELECTRIC | CONTROL PANEL, FIRE ALARM | CONTROL PANEL, SWITCHGEAR | |
ADDRESSABLE | ||||
AMP HOUR | ||||
AMPERAGE | ||||
CABINET TYPE | ||||
CONTROL VOLTAGE | ||||
DRAWING NUMBER | ||||
ENCLOSURE TYPE | ||||
FACLEVEL | ||||
FREQUENCY | ||||
FULL LOAD AMPS (FLA) | ||||
INSTALLER NAME | ||||
MOUNT HARDWARE TYPE | ||||
OUTDOOR RATED | ||||
PHASE | ||||
POWER | ||||
RACK ELEVATION | ||||
RADIO FREQUENCY | ||||
RATING | ||||
ROOM TYPE | ||||
STATION | ||||
TESTING | ||||
TYPE | ||||
VOLTAGE |
CHILD ASSETS
COMPONENTS & SPARE PARTS
UPDATES LOG
Operation Type | Type of Change | Old Value | New Value | Update Recorded (EST) |
---|---|---|---|---|
Create | ADS CODE | DIST90E-CBCT | 9/13/2021 10:59:25 AM | |
Create | ASSET NAME | CONTROL BOARD CABINET | 9/13/2021 10:59:25 AM | |
Create | ACRONYM | CBCT | 9/13/2021 10:59:25 AM | |
Create | PARENT (SUBSYSTEM) | CONTROLLER | 9/13/2021 10:59:25 AM | |
Create | CLASSIFICATION | CONTROL PANEL | 9/13/2021 10:59:25 AM | |
Create | FLOW Enabled | False | 9/13/2021 10:59:25 AM | |
Create | ACRM ASSET CLASS NUMBER | 5002; 10006; 99007 | 9/13/2021 10:59:25 AM | |
Create | ACRM ASSET DESCRIPTION | CONTROL EQUIPMENT - SWITCHING AND DISTRIBUTION; DEI-ICING PIPING AND EQUIPMENT; SNOW MELTING EQUIPMENT (NON-STRUCTURAL) | 9/13/2021 10:59:25 AM | |
Create | ACRM ASSET USEFUL LIFE | 25; 15; 15 | 9/13/2021 10:59:25 AM | |
Create | DEFAULT USEFUL LIFE | 20 | 9/13/2021 10:59:25 AM | |
Create | TAG STRATEGT | ON ASSET | 9/13/2021 10:59:25 AM | |
Create | TAG POSITION | SIDE | 9/13/2021 10:59:25 AM | |
Create | UNIFORMAT 2010 CODE(OPTION1) | D3070.10 | 9/13/2021 10:59:25 AM |