PUMP
HIERARCHY
Hierarchy Name | FUNCT |
System Name | CONDENSER WATER |
Subsystem Name | SOURCE |
Asset Name | PUMP |
Acronym | PUMP |
ADS Code | FUNCT20A-PUMP |
Definition | In a condenser water system, a pump is a device that circulates water through the condenser to facilitate heat exchange by moving cooled water from the cooling tower back to the condenser. |
FLOW Enabled | False |
Service Life | 20 YEARS |
Equipment Utilization | 50,000 HOURS |
STANDARD CROSSWALK
ACRM Asset Class Number | Reference cannot be found! |
ACRM Asset Description | Reference cannot be found! |
ACRM Asset Useful Life (yr) | Reference cannot be found! |
UniFormat 2010 Code (Option 1) | Reference cannot be found! |
UniFormat 2010 Code (Option 2) | Reference cannot be found! |
REQUIRED ASSET RECORDS
ENGINEERING ATTRIBUTES TABLE
Description | Attribute (ASSETATTRID) | UNIT OF MEASURE | DATA TYPE | DOMAIN ID |
---|---|---|---|---|
AMPERAGE AMP | PUMP_02 | AMP | NUM | |
CONFIGURATION | PUMP_21 | N/A | ALN | |
DIAMETER IN | PUMP_22 | IN | NUM | |
DRAWING NUMBER | PUMP_20 | N/A | ALN | |
FREQUENCY HZ | PUMP_03 | HZ | NUM | |
FULL LOAD AMPS (FLA) AMP | PUMP_10 | AMP | NUM | |
HEAD PRESSURE FT | PUMP_23 | FT | NUM | |
HORSEPOWER HP | PUMP_01 | HP | NUM | |
IMPELLAR DIAMETER IN | PUMP_16 | IN | NUM | |
LOCKED ROTOR AMPS (LRA) AMP | PUMP_11 | AMP | NUM | |
MATERIAL TYPE | PUMP_24 | N/A | ALN | |
MAX BRAKE HORSEPOWER BHP | PUMP_15 | BHP | NUM | |
MAXIMUM FLOW GPD | PUMP_13 | GPD | NUM | |
MAXIMUM FLOW RATE GPM | PUMP_19 | GPM | NUM | |
MAXIMUM KW INPUT KW | PUMP_12 | KW | NUM | |
MAXIMUM PRESSURE PSI | PUMP_06 | PSI | NUM | |
MAXIMUM SUCTION PRESSURE PSI | PUMP_18 | PSI | NUM | |
MAXIMUM WATER TEMPERATURE F | PUMP_07 | F | NUM | |
MOUNT | PUMP_25 | N/A | ALN | |
PHASE | PUMP_08 | N/A | ALN | _PHASE |
RATE BRAKE HORSEPOWER BHP | PUMP_14 | BHP | NUM | |
RATED PRESSURE PSI | PUMP_17 | PSI | NUM | |
RATING | PUMP_26 | N/A | ALN | |
SPEED RPM | PUMP_05 | RPM | NUM | |
STAGE | PUMP_09 | N/A | ALN | _STAGE |
TYPE | PUMP_27 | N/A | ALN | |
VOLTAGE V | PUMP_04 | V | NUM |
ASSET SUB TYPE AND ATTRIBUTES TABLE
PUMP | PUMP, CONDENSATE | PUMP, GEAR | PUMP, SUMP | PUMP, CIRCULATOR | PUMP, SEWAGE EJECTOR | PUMP, CENTRIFUGAL | PUMP, SUBMERSIBLE | PUMP, METERING | |
AMPERAGE AMP | |||||||||
CONFIGURATION | |||||||||
DIAMETER IN | |||||||||
DRAWING NUMBER | |||||||||
FREQUENCY HZ | |||||||||
FULL LOAD AMPS (FLA) AMP | |||||||||
HEAD PRESSURE FT | |||||||||
HORSEPOWER HP | |||||||||
IMPELLAR DIAMETER IN | |||||||||
LOCKED ROTOR AMPS (LRA) AMP | |||||||||
MATERIAL TYPE | |||||||||
MAX BRAKE HORSEPOWER BHP | |||||||||
MAXIMUM FLOW GPD | |||||||||
MAXIMUM FLOW RATE GPM | |||||||||
MAXIMUM KW INPUT KW | |||||||||
MAXIMUM PRESSURE PSI | |||||||||
MAXIMUM SUCTION PRESSURE PSI | |||||||||
MAXIMUM WATER TEMPERATURE F | |||||||||
MOUNT | |||||||||
PHASE | |||||||||
RATE BRAKE HORSEPOWER BHP | |||||||||
RATED PRESSURE PSI | |||||||||
RATING | |||||||||
SPEED RPM | |||||||||
STAGE | |||||||||
TYPE | |||||||||
VOLTAGE V |
CHILD ASSETS
COMPONENTS & SPARE PARTS
UPDATES LOG
Operation Type | Type of Change | Old Value | New Value | Update Recorded (EST) |
---|---|---|---|---|
Edit | DEFINITION | In a condenser water system, a pump is a device that circulates water through the condenser to facilitate heat exchange by moving cooled water from the cooling tower back to the condenser. | 4/3/2025 3:20:48 PM | |
Create | ADS CODE | FUNCT20A-PUMP | 3/28/2025 11:08:12 AM | |
Create | ASSET NAME | PUMP | 3/28/2025 11:08:12 AM | |
Create | ACRONYM | PUMP | 3/28/2025 11:08:12 AM | |
Create | PARENT (SUBSYSTEM) | SOURCE | 3/28/2025 11:08:12 AM | |
Create | CLASSIFICATION | PUMP | 3/28/2025 11:08:12 AM | |
Create | FLOW Enabled | False | 3/28/2025 11:08:12 AM |