ASSET TYPE CLASSIFICATION

Export Excel Spreadsheet


CLASSIFICATION NAME THRU-THE-WALL UNIT
Description AN AIR HANDLING UNIT DESIGNED TO BE INSTALLED THROUGH AN EXTERIOR WALL
Generate Description
Service Life 15 YEARS
Equipment Utilization 60,000 HOURS

ENGINEERING ATTRIBUTES TABLE

Description Attribute (ASSETATTRID) UNIT OF MEASURE DATA TYPE DOMAIN ID
COMPRESSOR LOCK ROTOR AMPS (LRA) AMP THRU_THE_WALL_UNIT_AHU_09 AMP NUM
COMPRESSOR RATED LOAD AMPS (RLA) AMP THRU_THE_WALL_UNIT_AHU_08 AMP NUM
COOLING AMPS AMP THRU_THE_WALL_UNIT_AHU_10 AMP NUM
COOLING BTU BTU THRU_THE_WALL_UNIT_AHU_04 BTU ALN
COOLING WATTS W THRU_THE_WALL_UNIT_AHU_11 W NUM
DRAWING NUMBER THRU_THE_WALL_UNIT_AHU_17 N/A ALN
FAN MOTOR FULL LOAD AMPS (FLA) AMP THRU_THE_WALL_UNIT_AHU_06 AMP ALN
FAN MOTOR HORSEPOWER HP THRU_THE_WALL_UNIT_AHU_07 HP NUM
FILTER SIZE THRU_THE_WALL_UNIT_AHU_15 N/A ALN
HEATING AMPS AMP THRU_THE_WALL_UNIT_AHU_12 AMP NUM
HEATING BTU BTU THRU_THE_WALL_UNIT_AHU_05 BTU ALN
HEATING WATTS W THRU_THE_WALL_UNIT_AHU_13 W NUM
HERTZ HZ THRU_THE_WALL_UNIT_AHU_03 HZ NUM
MERV RATING THRU_THE_WALL_UNIT_AHU_16 N/A NUM
NUMBER OF FILTERS THRU_THE_WALL_UNIT_AHU_14 N/A NUM
PHASE THRU_THE_WALL_UNIT_AHU_01 N/A ALN _PHASE
VOLTAGE V THRU_THE_WALL_UNIT_AHU_02 V NUM

ASSET SUB TYPE AND ATTRIBUTES TABLE

THRU-THE-WALL UNITTHRU-THE-WALL UNIT, COOLINGTHRU-THE-WALL UNIT, HEATING AND COOLING
COMPRESSOR LOCK ROTOR AMPS (LRA) AMP
COMPRESSOR RATED LOAD AMPS (RLA) AMP
COOLING AMPS AMP
COOLING BTU BTU
COOLING WATTS W
DRAWING NUMBER
FAN MOTOR FULL LOAD AMPS (FLA) AMP
FAN MOTOR HORSEPOWER HP
FILTER SIZE
HEATING AMPS AMP
HEATING BTU BTU
HEATING WATTS W
HERTZ HZ
MERV RATING
NUMBER OF FILTERS
PHASE
VOLTAGE V


RELATED FUNCTIONAL ASSET CLASSIFICATION


PROBLEMS, CAUSES, & REMEDIES


UPDATES LOG

Operation Type Type of Change Old Value New Value Update Recorded (EST)
Edit Field Change FAN MOTOR FULL LOAD AMPS (FLA)(THRU_THE_WALL_UNIT_AHU_06) FAN MOTOR FULL LOAD AMPS (FLA) AMP(THRU_THE_WALL_UNIT_AHU_06) 5/9/2025 12:27:10 PM
Edit Field Change FAN MOTOR HORSEPOWER(THRU_THE_WALL_UNIT_AHU_07) FAN MOTOR HORSEPOWER HP(THRU_THE_WALL_UNIT_AHU_07) 5/9/2025 12:27:10 PM
Edit Field Change HEATING AMPS(THRU_THE_WALL_UNIT_AHU_12) HEATING AMPS AMP(THRU_THE_WALL_UNIT_AHU_12) 5/9/2025 12:27:10 PM
Edit Field Change HEATING BTU(THRU_THE_WALL_UNIT_AHU_05) HEATING BTU BTU(THRU_THE_WALL_UNIT_AHU_05) 5/9/2025 12:27:10 PM
Edit Field Change HEATING WATTS(THRU_THE_WALL_UNIT_AHU_13) HEATING WATTS W(THRU_THE_WALL_UNIT_AHU_13) 5/9/2025 12:27:10 PM
Edit Field Change HERTZ(THRU_THE_WALL_UNIT_AHU_03) HERTZ HZ(THRU_THE_WALL_UNIT_AHU_03) 5/9/2025 12:27:10 PM
Edit Field Change VOLTAGE(THRU_THE_WALL_UNIT_AHU_02) VOLTAGE V(THRU_THE_WALL_UNIT_AHU_02) 5/9/2025 12:27:10 PM
Edit Data Type Change (VOLTAGE V(THRU_THE_WALL_UNIT_AHU_02)) ALN NUM 5/9/2025 12:27:10 PM
Edit Field Change COOLING WATTS(THRU_THE_WALL_UNIT_AHU_11) COOLING WATTS W(THRU_THE_WALL_UNIT_AHU_11) 5/9/2025 12:27:10 PM
Edit Field Change COOLING AMPS(THRU_THE_WALL_UNIT_AHU_10) COOLING AMPS AMP(THRU_THE_WALL_UNIT_AHU_10) 5/9/2025 12:27:10 PM
Edit Field Change COMPRESSOR LOCK ROTOR AMPS (LRA)(THRU_THE_WALL_UNIT_AHU_09) COMPRESSOR LOCK ROTOR AMPS (LRA) AMP(THRU_THE_WALL_UNIT_AHU_09) 5/9/2025 12:27:10 PM
Edit Field Change COMPRESSOR RATED LOAD AMPS (RLA)(THRU_THE_WALL_UNIT_AHU_08) COMPRESSOR RATED LOAD AMPS (RLA) AMP(THRU_THE_WALL_UNIT_AHU_08) 5/9/2025 12:27:10 PM
Edit Field Change COOLING BTU(THRU_THE_WALL_UNIT_AHU_04) COOLING BTU BTU(THRU_THE_WALL_UNIT_AHU_04) 5/9/2025 12:27:10 PM
Edit CLASSIFICATION NAME THRU-THE-WALL UNIT (TYPE OF AHU) THRU-THE-WALL UNIT 11/8/2024 11:40:48 AM
Edit SUBCLASSIFICATION NAME THRU-THE-WALL UNIT (TYPE OF AHU), COOLING THRU-THE-WALL UNIT, COOLING 11/8/2024 11:40:48 AM
Edit SUBCLASSIFICATION NAME THRU-THE-WALL UNIT (TYPE OF AHU), HEATING AND COOLING THRU-THE-WALL UNIT, HEATING AND COOLING 11/8/2024 11:40:48 AM
Delete ADS CODE FUNCT96I-GBTH-HVAC 8/9/2024 10:16:46 AM
Edit ADS CODE PORT96I-GBTH-HVAC FUNCT96I-GBTH-HVAC 8/9/2024 10:16:46 AM
Edit Description AN AIR HANDLING UNIT DESIGNED TO BE INSTALLED THROUGH AN EXTERIOR WALL 7/17/2024 4:10:02 PM
Edit Service Life 15 YEARS 7/17/2024 4:10:02 PM
Edit Equipment Utilization 60,000 HOURS 7/17/2024 4:10:02 PM
Delete ADS CODE FUNCT06B-TTWU 3/20/2024 2:11:23 PM
Edit ADS CODE BLDG06B-TTWU FUNCT06B-TTWU 3/20/2024 2:11:23 PM
Delete ADS CODE FUNCT06A-TTWU 3/20/2024 12:17:26 AM
Edit ADS CODE BLDG06A-TTWU FUNCT06A-TTWU 3/20/2024 12:17:26 AM
Edit Field Change FAN MOTOR HORSE POWER(THRU_THE_WALL_UNIT_AHU_07) FAN MOTOR HORSEPOWER(THRU_THE_WALL_UNIT_AHU_07) 1/5/2022 11:08:04 AM
Edit Field Change COMPRESSOR RATED LOAD AMPERAGE (RLA)(THRU_THE_WALL_UNIT_AHU_08) COMPRESSOR RATED LOAD AMPS (RLA)(THRU_THE_WALL_UNIT_AHU_08) 1/5/2022 11:08:04 AM
Create Field Change FAN MOTOR FULL LOAD AMPS (FLA)(THRU_THE_WALL_UNIT_AHU_06) 10/1/2021 5:55:51 PM
Create Field Change FAN MOTOR HORSE POWER(THRU_THE_WALL_UNIT_AHU_07) 10/1/2021 5:55:51 PM
Create Field Change HEATING AMPS(THRU_THE_WALL_UNIT_AHU_12) 10/1/2021 5:55:51 PM
Create Field Change HEATING BTU(THRU_THE_WALL_UNIT_AHU_05) 10/1/2021 5:55:51 PM
Create Field Change HEATING WATTS(THRU_THE_WALL_UNIT_AHU_13) 10/1/2021 5:55:51 PM
Create Field Change HERTZ(THRU_THE_WALL_UNIT_AHU_03) 10/1/2021 5:55:51 PM
Create Field Change VOLTAGE(THRU_THE_WALL_UNIT_AHU_02) 10/1/2021 5:55:51 PM
Create Field Change COOLING WATTS(THRU_THE_WALL_UNIT_AHU_11) 10/1/2021 5:55:51 PM
Create Field Change COOLING AMPS(THRU_THE_WALL_UNIT_AHU_10) 10/1/2021 5:55:51 PM
Create Field Change COMPRESSOR LOCK ROTOR AMPS (LRA)(THRU_THE_WALL_UNIT_AHU_09) 10/1/2021 5:55:51 PM
Create Field Change COMPRESSOR RATED LOAD AMPERAGE (RLA)(THRU_THE_WALL_UNIT_AHU_08) 10/1/2021 5:55:51 PM
Create Field Change COOLING BTU(THRU_THE_WALL_UNIT_AHU_04) 10/1/2021 5:55:51 PM
Create Field Change FILTER SIZE(THRU_THE_WALL_UNIT_AHU_15) 10/1/2021 5:55:51 PM